Passive air cooling for femtosecond lasers
Why Indylit lasers need no chiller, what that changes for the machine builder, and how to plan the cabinet for the heat that remains.
What passive cooling means.
The laser heads of Indylit 20, Indylit 10 and Indylit 3 are cooled by passive air: the heat leaves through the housing, with no chiller and no water lines. The control unit is cooled by built-in fans. The patented passive cooling design was developed with FTMC (Center for Physical Sciences and Technology).
Indylit 20 is a 20 W production femtosecond laser with a passive air-cooling system. For setups that need it, Indylit 20 also takes an optional water coldplate on the head.
What changes on the machine.
No water in the machine
A water-cooled laser needs a chiller beside the machine, hoses through its frame and coolant that has to stay clean. Each is one more part to buy, power, service and fit, and one more part that can stop production. A passively cooled laser head has nothing to plumb, top up or leak.
Laser heads where the process needs them
The Indylit 20 head measures 482 × 248 × 143 mm. Without hoses it can sit on the motion system, close to the process optics, and several heads can run side by side in one machine with no shared chiller to size.
Lower running cost
A chiller draws its own power for as long as the laser runs. At 0.5 kW, 6,000 hours a year and 0.15 €/kWh, that is 450 € a year in electricity alone, before its price and maintenance. The laser chiller cost calculator works it out with your own values.
Planning the cabinet.
The heat does not disappear: an air-cooled laser releases it into the air around it. Indylit 20 draws about 300 W on average after warm-up and Indylit 10 about 200 W, with a 700 W maximum rating for both. Plan the cabinet ventilation for that heat.
Airflow to remove the heat
V̇ = P / (ρ · cp · ΔT)
With air at ρ ≈ 1.2 kg/m³ and cp ≈ 1,005 J/(kg·K), removing 300 W with a 5 K temperature rise across the cabinet takes about 0.05 m³/s, or 180 m³/h. With a 10 K rise it is about 90 m³/h.
A stable environment
Keep the air around the laser within 18–33 °C (18–32 °C for Indylit 3), non-condensing, and stable. Beam pointing changes by less than 20 µrad per °C (15 µrad per °C for Indylit 3), and the datasheets give the stability figures for a room temperature held within ±1 °C. The integration check lists the power draw, heat and operating range for each laser.
Questions.
Do Indylit 20 and Indylit 10 need a chiller?
No. The laser head is cooled by passive air and the control unit by built-in fans. Only the optional water coldplate for Indylit 20 needs one, supplying more than 1 L/min at 25–33 °C; it is not included.
When does the water coldplate make sense?
When the cabinet cannot take the heat of the laser head, for example in a closed enclosure or a warm environment. Discuss the setup with an engineer before you design around it.
How much heat goes into the cabinet?
About 300 W with Indylit 20 and 200 W with Indylit 10 on average after warm-up. At a 5 K rise across the cabinet, 300 W needs about 180 m³/h of air.
How many LITILIT lasers are in the field?
More than 1,000 LITILIT lasers are installed worldwide.
Related tools.
Indylit integration check · Laser chiller cost calculator · Cycle time and cost per part · Indylit power and pulse energy · All laser tools
Building a machine around a femtosecond laser?
Tell us about the system, the volumes and the timeline. A LITILIT engineer will walk through the integration with your team.